ASME A112.19.3-2000 pdf free download

ASME A112.19.3-2000 pdf free download

ASME A112.19.3-2000 pdf free download.STAINLESS S’ ‘EEL PLUMBING FIXTURES (DESIGNED FOR RESIDENTIAL USE)
2.2 Surface Finish Ail fixture surfaces shall be free from die marks, blemishes, wrinkles, and roping when inspected as described in para. 4.1. (See para. 1.6 for definitions.)
2.3 Construction of Stainless Steel Fixtures Sink and lavatory fixtures shall be either drawn se.amless or welded. Welds shall be ground and polished where exposed so as to produce continuously smooth, even surfaces. They shall be cleaned after polishing. Sink compartments and drainboards shall be treated with effective sound-inhibiting material.
The coverage and type of sound-inhibiting material used shall be in ac:cordance with the Manufacturer’s regular practice.
2.3.1 Kitchen Sink Flanges (See Para. 1.6 for Definition). Flanges on kitchen sinks shall be flat, rigid, and otherwise suitable for effective installation of the fixture by the use of conventional sink frames (see para. 4.2), or shall provide a means for attachment without sink frames. Exposed edges shall be smooth and free from burrs and sharp edges. On kitchen sinks without integral rims, flanges shall not be more than 2 in. (50 mm) in width when measured as shown in Fig. 1, sketch (a). On sinks with integral rims, flanges shall not be more than 292 in. (64 mm) in width when measured as shown in Fig. 1, sketch (b).
2.3.2 Kitchen Sink Ledges (See Para. 1.6 for Definition). Ledges at the back of kitchen sinks shall be flat, rigid, and otherwise suitable for effective installa- tion of fittings (see para. 4.2). Exposed edges shall be smooth and free from burrs and sharp edges. On ledge- back kitchen sinks without integral rims, ledges shall not be more than 5 in. (127 mm) in width when measured as shown in Fig. 2, sketch (a). On ledgeback kitchen sinks with integral rims, ledges shall not be more than 5% in. (140 mm) in width when measured as shown in Fig. 2, sketch (b).
2.3.3 Kitchen Sink Drainboards. Drainboards (as shown in Tables A7 through A13) shall be fastened to sink compartments, and shall be formed by stamping, pressing, fabrication, or combination thereof. The drain area of a drainboard sink shall be at least /16 in. (5 mm) below flood level at a location farthest from the bowl, and shall have a fall towards the bowl. Drainboards shall be smooth ribbed or grooved. All ribs or grooves shall run parallel with the slope of the drainboard.
2.3.3.1 Welded Kitchen Sink Drainboards. Drainboard sinks using welded construction shall be fastened to sink compartments with continuous welds having visible surfaces of the weld ground smooth, and free from cracks and pits. Corners of drainboards on cabinet sink tops shall be welded and ground smooth.
2.4 Dimensions and Tolerances Fixtures shall conform to tile applicable dimensions and tolerances given herein. Where not otherwise indicated, a tolerance of plus or minus 1% shall apply. Maximum and minimum dimensions are not subject to a tolerance beyond the stated limits, except where given as nominal dimensions.
3 FIXTURE TYPES AND SIZES
3.1 Kitchen Sinks Common types and sizes are:
(a) fat-rim sink, single compartment (see Table Al);
(b) fat-rim sink, double compartment (see Table A2);
(c) ledge-back sink, single compartment (see Ta- ble A3);
(d) ledge-back sink, double compartment (see Ta- ble A4);
(e) ledge -back sink and tray combinations (see Ta- ble A5);
(f) ledge-back two-level sink, double compartment (see Table A6);
(g) ledge-back sink, single compartment with single drainboard (see Table A7);
(h) ledge-back sink, double compartment with single drainboard (see Table A8);
(i) ledge-back sink, single compartment with double drainboard (see Table A9);
(j) ledge-back sink, double compartment with double drainboard (see Table A10);
3.2 Bar Sinks Common types and sizes are:
(a) ledge-back sink, single compartment (see Table A16); and
(b) ledge-back sink, double compartment (see Ta- ble A17).
3.3 Lavatories (See Fig. A1) Common types of flat-rim lavatories are rectangular, round, or oval; with or without back ledge; and with or without integral rims. Flanges shall be flat, rigid, and suitable for effective installation of the fixtures (see para. 4.2). .
3.3.1 Lavatory Overflows. When provided, lava- tory overflows shall have either a minimum Cross- sectional area not less than 1%g in2 (725 mm) at every point in the passageway or shall have a minimum flow capacity (as specified in ASME A112.18.1 for lavatory faucets) when tested in accordance with para. ASME A112.19.3 pdf download.ASME A112.19.3-2000 pdf free download